Exploded view & dismantling sequence of parts
- 18 -
3. Dismantling sequence of indoor unit of FR95-C and FR125-C/S
(1) Remove 1
(2) Remove 11, 14
(3) Remove 2
(4) Remove 4, 3
(5) Remove 21
(6) Remove 9, 10
(7) Remove 12, 13
(8) Remove 8
(9) Remove 7
(10) Remove 22
(11) Remove 19
(12) Remove 20
(13) Remove 5, 18, 17
(14) Remove 15
Annex: Dismantling sequence of typical parts
Indoor capacitor:
(1) Remove 1
(2) Remove 11, 14
(3) Remove capacitor.
Indoors motor:
(1) Remove electric box 4
(2) Remove cover plate 2 and strainer frame 11
(3) Remove plug of indoor motor from control board in electric box
(4) Remove fan mounting plate 21
(5) Remove spiral casing 9 and impeller 10
(6) Remove motor support 13
(7) Remove motor 12 and capacitor.