Main technical parameters
- 35 -
Cooling: 15℃<T32 (indoor) Heating: 12℃<T27 (indoor)
18℃<T43 (outdoor) -7℃<T24 (outdoor)
3. Value in “( )” is nominal value of auxiliary electric heating;
4. Return air port size based on optional return air box size.
II. Main technical parameters for FR(D)71-B and FR(D)100-B
Model FR71-B FRD71-B FR100-B FRD100-B
Rated cooling capacity 7100W 10000W
Rated heating capacity 7500W 75002300W 10500W
105002300
W
Power supply 220V50Hz
Cooling 2760W 3900W
Rated input
power
Heating 2420W 3100W
Cooling 13.4A 17.8A
Rated input
current
Heating 11.8 A 11.8(10.5) A 14.2 A 14.2(10.5) A
Air circulation flow 1500 m
3
/h 2000 m
3
/h
Air exhaust static pressure 30Pa
Indoor unit noise 54dB(A) 56dB(A)
Outdoor unit noise 60 dB(A) 62dB(A)
Indoor unit 44 Kg 46 Kg 60 Kg 62 Kg
Mass
Outdoor unit 78 Kg 85 Kg
Filling of refrigerant R22/2.7 Kg R22/3.3 Kg
Liquid pipe
Liquid pipe φ10×1
Conn. pipe
size (user)
Steam pipe
Steam pipe φ16×1
Ind. unit mm 1260×555×226 mm 1880×555×226 mm Outline
W×D×H
Outd Unit mm 950×370×746 mm 950×420×853 mm
Notes:
(1) Length of connecting pipe for test: 7.5m
(2) Operating environment (T):
Cooling: 15℃<T32 (indoor)
18℃<T43 (outdoor)
Heating: 12℃<T27 (indoor)
-7℃<T24 (outdoor)