Do you have a question about the CIAT DynaCIAT LG and is the answer not in the manual?
Safety guidelines for installation, start-up, and servicing operations.
Precautions for electrical components and safe work practices.
Overview of the Connect Touch control system and its features.
Details on compressor, fan, and safety device control.
Explanation of Local, Remote, and Network operating modes.
Description of main controller (Connect Touch) and SIOB boards.
Information on power supply, LED indicators, and connections.
Details on communication protocols and ports for Connect Touch.
Types and functions of pressure transducers used in the system.
Description of various temperature sensors and their roles.
Information on actuators like EXV, pumps, boiler, and electric heaters.
Summary of terminal block connections for various functions.
Recommended wiring schemes for RS485 communication.
Description of the 4.3-inch Connect Touch screen and its features.
Explanation of the Home screen layout and navigation elements.
Details on information messages and warning prompts.
Procedure for screen calibration and saving modifications.
Description and function of header and other control buttons.
Overview of the Main menu structure and its categories.
Detailed parameters for General, Temperature, Pressure, Inputs, and Outputs.
Status information for pumps, runtime data, and air condensers.
Status for DC Free Cooling, miscellaneous items, and operating modes.
Software options, quick tests, and trending features.
Configuration of general unit settings and pump parameters.
Configuration for cooling/heating modes, resets, and date/time.
Configuration of unit schedules and holiday periods.
Network, BACnet, Modbus, email, and control identification configurations.
System settings, login procedures, and unit start/stop operations.
Monitoring alarms and resetting active alarms.
Summary of unit start/stop control logic based on various factors.
Function of interlock contact and management of cooling/heating modes.
Control options for boilers and electric heating stages.
Definition, verification, and management of control points and setpoints.
Heat exchanger water pump control, speed, protection, and ECO mode.
Adjusting compressor stages and setting unit capacity limits.
Control of condensing pressure and Dry Cooler Free Cooling functionality.
Master/slave assembly, night mode, brine, BACnet, and Modbus options.
Explanation and installation of software activation keys for unit options.
Setting unit schedules and defining holiday periods.
Visualizing unit operations via trends and performing quick tests.
Accessing and controlling unit parameters via a web browser.
Accessing technical documents related to the product.
Overview of fault tracing, alarm triggering, and viewing current alarms.
Configuring email notifications and resetting active alarms.
Accessing alarm history and detailed descriptions of Jbus alarms.