68
CLEANING THE CONDENSER WITH A BRUSH
A) SWITCH OFF the machine and disconnect it from the power supply mains.
B) OPEN the panel covering the motor compartment.
C) PROCEED to clean the condenser taking care to use the brush in a downwards direction from the top.
CLEANING THE CONDENSER WITH COMPRESSED AIR
A) SWITCH OFF the machine and disconnect it from the power supply mains.
B) OPEN the sides and the panel covering the motor compartment.
C) PROCEED to clean the condenser using a jet of air to blow from the inside to the outside and from the top to the bottom.
During these operations, it is advisable to check the state of the component parts.
CLEANING THE WATER-COOLED CONDENSER
For units with water-cooled condensers it is advisable for a plumber to carry out cleaning operations using the proper, commer
-