Raption Series User Manual
Value Description
ID Tag Endianness Storage type for system data. Able to choose between
(LITTLE>BIG)
Include Power Active
Import in MeterValues
ENABLED: Send power (Power.Active.Import) and energy
(Energy.Active.Import.Register) consumed by the vehicle
within meter values requests.
DISABLED: Only enrgy consumed is sent within meter
values request.
Energy for Start/Stop
transaction
PARTIAL: Consumed value of energy by the vehicle sent
between start and stop.
TOTAL: Count of the total accumulated energy meter sent
between start and stop.
User confirmation on HMI
required on Remote Start
Transaction
ENABLED: Charge point sends an authorization request
before starting a new remote charge transaction request.
DISABLED: Charge point starts a new remote charge
transaction without authorization request.
Authorize always in offline
mode
ENABLED: If user is not present locally in the local white-
list and charge point cannot ask to the backend, the user is
allowed to start a new charge transaction.
DISABLED: If user is not present locally in the local white-
list and charge point cannot ask to the backend, the user is
not allowed to start a new charge transaction.
Authorization check order
LOCAL: ID authorization has first place on the local white-
list. If the user does not exist locally, then in second place
backend is asked to obtain the authorization.
CS: ID authorization is always asked to the backend.
*NOTE: This setting only applies when Charge Point is
online; otherwise the authorization is only locally.