84
Value Description
Use OCPP time
synchronization
ENABLED: Synchronization of date and time.
DISABLED: Synchronization of date and time.
*NOTE: Date and Time is sent from backend on each
heartbeat response.
Energy for MeterValues
PARTIAL: Sends partial energy consumption while vehicle
is charging.
TOTAL: sends the actual count of the total accumulated
energy meter.
Stop charge if StartTrans-
action rejects the user
ENABLED: Stop existing charge transaction after
response from backend (StartTransaction.conf) when user
is blocked, expired or Invalid.
DISABLED: Charge transaction does not stops even if
backend rejects the user. (StartTransaction.conf)
*NOTE: Set this option according to your backend system.
Authorize Remote Tx
Requests
ENABLED: The Charge Point asks for authorization when
the Central System sends a remote start.
DISABLED: The Charge Point starts the Charge
Transaction when the Central System sends a remote start.
Stop charge if
StartTransaction replies
ConcurrentTx
ENABLED: Stop existing charge transaction after
response from backend (StartTransaction.conf) when user
has already involved in another transaction.
DISABLED: Charge transaction does not stops even if
backend rejects the user. (StartTransaction.conf)
*NOTE: Set this option according to your backend system.