Ensure O-Rings are clean and in good condition.
Threaded collars are cross-threaded or
pipes are misaligned
Inspect threads for damage, ensure that each
screws back on without resistance.
Cell frequently has mineral
buildup
This is due to imbalanced water chemistry
and a high Saturation Index
Ensure that your Saturation Index is at or near
zero, in order to avoid damage or premature cell
failure. (page 8)
Cell never or rarely has mineral
buildup
Water may be corrosive due to imbalanced
water chemistry and a low Saturation Index
Ensure that your Saturation Index is at or near
zero, in order to avoid damage or premature cell
failure. (page 8)
Water temp is less than 64°. No further action req.
Chlorine Output level does not
reach 100%
Clean Cell (see page 11).
Damaged Cell or Cell cable
Contact Customer Support.
If salinity is within range, system has reached
the end of its lifespan, cell blades are worn.
Cell is reaching its working capacity limit. Cell
must be replaced once “Cell Life Low” LED is on
and Chlorine Output setting won’t reach 100%.
Replacement cells are readily available for
purchase from your local dealer or at
www.circupool.com
System Error LED is blinking
Debris is stuck in the electrical connection
between Cell and Control Module
Remove Control Module from the Cell. Clean the
electrical connection from any debris stuck in it.
Wipe with a dry cloth.
Other communication problem between Cell
and Control Module
Debris is stuck in the electrical connection
between Cell and Control Module
Remove Control Module from the Cell. Clean the
electrical connection from any debris stuck in it.
Wipe with a dry cloth.
Cell blades are dirty or worn
Inspect Cell for debris or scaling, clean if
necessary. Replace Cell if damaged or worn.
A more serious error has occurred
Contact Customer Support.
Salt level may be greatly out of range
Manually verify salinity (see pages 6-7).
For more information or troubleshooting, visit www. circupool.com/help