P/N 11935-006 A - 5
CIRRUS PILOT’S CHECKLIST MODEL SR20
Fuel Imbalance
FUEL IMBALANCE Caution
1. Fuel Quantity Gages...........................................................CHECK
2. Fuel Pump ................................................................................. ON
If Fuel Pump is already ON for vapor suppression, pump
should be left in this position for tank switch.
3. Fuel Selector ......................................... SELECT FULLEST TANK
4. Fuel Pump ..............................................................AS REQUIRED
After switching tanks, message will remain until sensed
imbalance is less than 7.5 gallons.
Electrical System
Low Voltage on Main Bus 1
M BUS 1 Caution
1. Perform Alt 1 Caution (Failure) Checklist.
Low Voltage on Main Bus 2
M BUS 2 Caution
1. Perform Alt 1 Caution (Failure) and Alt 2 Caution (Failure) Checklists.
Battery 1 Current Sensor
BATT 1 Caution
1. Main Bus 1, 2 and Non-Essential Bus Loads .................. REDUCE
2. Main Bus 1, 2 and Essential Bus Voltages .....................MONITOR
3. Land as soon as practicable.