E - 4 P/N 11935-006
CIRRUS PILOT’S CHECKLIST MODEL SR20
Smoke and Fire
Engine Fire In Flight
1. Mixture..............................................................................CUTOFF
2. Fuel Pump ............................................................................... OFF
3. Fuel Selector ........................................................................... OFF
4. Airflow Selector........................................................................ OFF
5. Power Lever ........................................................................... IDLE
6. Ignition Switch ......................................................................... OFF
7. Cabin Doors.......................................................PARTIALLY OPEN
8. Land as soon as possible.
Cabin Fire In Flight
1. Bat-Alt Master Switches ........................................OFF, AS REQ’D
2. Fire Extinguisher.............................................................ACTIVATE
If airflow is not sufficient to clear smoke or fumes from cabin:
3.
Cabin Doors.......................................................PARTIALLY OPEN
4. Avionics Power Switch............................................................. OFF
5. All other switches..................................................................... OFF
6. Land as soon as possible.
If setting master switches off eliminated source of fire or fumes
and airplane is in night, weather, or IFR conditions:
7. Airflow Selector........................................................................ OFF
8. Bat-Alt Master Switches ............................................................ON
9. Avionics Power Switch...............................................................ON
10. Required Systems ...............................ACTIVATE ONE AT A TIME
11. Temperature Selector ........................................................... COLD
12. Vent Selector ........................ FEET/PANEL/DEFROST POSITION
13. Airflow Selector...............................SET AIRFLOW TO MAXIMUM
14. Panel Eyeball Outlets ........................................................... OPEN
15. Land as soon as possible.