Power Supply 1300W AC 2800W AC 4200W AC 6000 AC 9000 AC 1400W DC with Power Entry
Module (PEM)
Output current
(PoE)
-50V at 16.7A -50V at 28A -50V at 77.1A
(200V)
-50V at 38A
(100V)
-50V at 100.0A
(200V)
-50V at 38.5A
(120V)
-50V at 150.0A
(200V)
-50V at 50.0A
(120V)
140A at -48/-60 VDC
Output power
redundant mode
(data)
1000W + 40W 1360W + 40W 1383W + 40W 2200W + 40W 1960W + 40W 1360W + 40W
Output power
redundant mode
(PoE)
800W
maximum per
power supply
1400W
maximum per
power supply
3700W
(220V)
1850W
(110V)
4800W
(220V)
1850W
(110V)
7500W
(220V)
2500W
(110V)
Up to 7500W (minus the power
consumed for data)
Output power
combined mode
(data)
1667W 2473W 2766W 4400W 3920W -
Output power
combined mode
(PoE)
1333W 2333W 6700W (220V)
3360W (110V)
8700W (220V)
3360W (110V)
14,400W
(220V)
4150W (110V)
3800W (100V)
Heat dissipation 1568 BTU/hr 2387 BTU/hr 3580 BTU/hr 2720 BTU/hr 3010
BTU/hr
Data only: 1591 Btus per hour
Data and voice: 2905 Btus per
hour
Holdup time 20 ms 20 ms 20 ms 20 ms 20 ms 4 ms
Hot swappable Yes Yes Yes Yes Yes Yes
Additional notes for Tables 7 and 8:
Output power is per power supply unless otherwise stated.
Heat-dissipation numbers represent the power-conversion losses of the power supply in operation.
The number of power devices supported depends on customer configuration.
Fan Trays
Each Cisco Catalyst 4500E Series uses a single fan tray for cooling. All fan trays are composed of independent
fans. If one fan fails, the system will continue to operate without a significant degradation in cooling. The system
will detect and notify the user (through LED, CLI, and Simple Network Management Protocol [SNMP]) that a fan
has failed and the tray needs to be replaced.
Environmental Conditions
The Cisco Catalyst 4500 and 4500E Series require the following conditions:
Operating temperature: 32 to 104ºF (0 to 40ºC)
Storage temperature: -40 to 167ºF (-40 to 75ºC)
Relative humidity: 10 to 90 percent, noncondensing
Operating altitude: -60 to 3000 meters (m)

Other manuals for Cisco Catalyst 4500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4500 Series and is the answer not in the manual?

Cisco Catalyst 4500 Series Specifications

General IconGeneral
SeriesCatalyst 4500 Series
CategorySwitch
Layer SupportLayer 2, Layer 3
Form FactorModular chassis
StackableNo
Chassis Slots3, 6, 7, 10
Power Supply OptionsAC, DC
RedundancyPower supply, Supervisor engine
Network ManagementCisco IOS Software CLI, SNMP, Cisco Prime Infrastructure
FeaturesSecurity, QoS
Port DensityUp to 384 ports per chassis
Security Features802.1X, ACLs, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard
Supervisor Engine8-E

Related product manuals