Page #26 background imageLoading...
Page #26 background image
Cable distance
Half the
distance
specified by
the IEEE
standard.
Note
Modal bandwidth
(MHz/km)
Core diameter (microns)
110 m
137 m
250 m
275 m
500 m
160 (FDDI)
200 (OM1)
400
500 (OM2)
2000 (OM3)
62.5
62.5
50
50
50
Cable and operating
distance
Table 3: 10-G SR Network Module (FPR2K-NM-6X10SR-F)
MaximumTypicalOperating Mode
1.4 dB
1.7 dB
0.9 dB
1.2 dB
Normal
Hardware bypass
Insertion loss
Cable distance
Half the
distance
specified by
the IEEE
standard.
Note
Modal bandwidth
(MHz/km
Core diameter (microns)
13 m
16.5 m
33 m
41 m
150 m
200 m
160 (FDDI)
200 (OM1)
400
500 (OM2)
2000 (OM3)
4700 (OM4)
62.5
62.5
50
50
50
50
Cable and operating
distance
Table 4: 10-G LR Network Module (FPR2K-NM-6X10LR-F)
MaximumTypicalOperating Mode
1.6 dB
1.9 dB
1.2 dB
1.5 dB
Normal
Hardware bypass
Insertion loss
Cisco Firepower 2100 Series Hardware Installation Guide
22
Overview
1-G SX/10-G SR/10-G LR Network Module with Hardware Bypass

Other manuals for Cisco Firepower 2110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 2110 and is the answer not in the manual?

Cisco Firepower 2110 Specifications

General IconGeneral
Rack Units1 RU
Operating Temperature32°F to 104°F (0°C to 40°C)
Humidity10% to 90% non-condensing
Maximum Concurrent Sessions2, 000, 000
AVC Throughput2.2 Gbps
Interfaces8 x 1G, 2 x 10G SFP+
Power SupplyAC
Dimensions (H x W x D)1.72 x 17.3 x 16.5 in
Storage Temperature-4°F to 149°F (-20°C to 65°C)