Statement 1002DC Power Supply
When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type
with upturned lugs. These terminations should be the appropriate size for the wires and should clamp both
the insulation and conductor.
Warning
Statement 1003DC Power Disconnection
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Statement 1015Battery Handling
There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions.
Warning
Statement 1022Disconnect Device
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Warning
Statement 1025Use Copper Conductors Only
Use copper conductors only.
Warning
Statement 1030Equipment Installation
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1046Installing or Replacing the Unit
When installing or replacing the unit, the ground connection must always be made first and disconnected
last.
Warning
Statement 1073No User-Serviceable Parts
No user-serviceable parts inside. Do not open.
Warning
Cisco Firepower 2100 Series Hardware Installation Guide
47
Maintenance and Upgrades
Remove and Replace the Power Supply Module

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 2120 and is the answer not in the manual?

Cisco Firepower 2120 Specifications

General IconGeneral
Form Factor1RU
Memory16 GB
Operating Temperature32 to 104°F (0 to 40°C)
Maximum Concurrent Sessions2, 000, 000
Maximum Connections2 million
Management Ports1 x 1G management port
Storage480 GB SSD
Power SupplyDual, hot-swappable power supplies
Interfaces8 x 1GE, 8 x 1GE SFP

Related product manuals