FLI Module Installation
WARNING:
Laser light hazard. Never look into the end of an optical fiber or connector.
Failure to observe this warning can result in eye damage or blindness.
3 Loosen the screws securing the module.
4 Lift the module straight up out of the housing to unplug it.
Note: Pull up on the built-in handle.
5 To install a module, position it in the desired location and carefully slide the
module into its slot until connected to the optical interface board.
6 Tighten the screws securing the module. Torque screws from 25 to 30 in-lbs (2.8
to 3.4 Nm).
7 Carefully reconnect any optical fibers that were removed from the original
module.
Important: Clean optical connectors before reconnecting. Follow recommended
fiber optic cleaning procedures.
WARNING:
Laser light hazard. Never look into the end of an optical fiber or connector.
Failure to observe this warning can result in eye damage or blindness.
8 Close the node housing. Refer to Closing the Housing for complete instructions.