8 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide
exit
telnet server enable
no ssh server enable
Would you like to edit the configuration? (yes/no) [n]: n
Use this configuration and save it? (yes/no) [y]: y
[########################################] 100%
Copy complete, now saving to disk (please wait)...
Log in with the credentials created in the previous steps.
2.4 Configure the vPC domain
switch# configure
switch(config)#feature lacp
switch(config)#feature vpc
switch(config)#vpc domain 1
switch(config-vpc-domain)#peer-keepalive destination peer IP address
--------:: Management VRF will be used as the default VRF ::--------
Note: For the <
peer IP address>
, use the management IP address of the partner switch.
switch(config-vpc-domain)#exit
2.5 Enable link level flow control (802.3x)
You must perform this step for each individual port that is connected to a storage controller or a host
interface port, or you can specify a range of ports to configure.
switch(config)#interface ethernet 1/1-32
switch(config-if-range)#priority-flow-control mode off
switch(config-if-range)#flowcontrol send on
switch(config-if-range)#flowcontrol receive on
switch(config-if-range)#exit
2.6 Configure Port Channel
switch(config)# interface port channel 1