Uplink Module LEDs
The Status (STS) LED is located on the left side of the uplink module. There is an ACT LED located below
each two uplink ports. Next to each ACT LED are two triangular port LEDs that point to the top or bottom
to identify their port as being the top or bottom port.
StatusColorLED
This module is operational.GreenSTS
Temperature is not operational.Red
The module is not receiving power.Off
The two ports above this LED are enabled.
On (white)ACT
The two ports above this LED are not enabled.Off
The port is connected with a transceiver or other connector.
Green(port)
The port is not connected.Off
Fan Module LEDs
The fan module status LED is located on the front of the module.
StatusColorLED
The fan module is operational.GreenStatus
The fan module is not operational (fan is probably not functional).Red
Fan module is not receiving power.Off
Power Supply LEDs
The power supply LEDs are located on the left right portion of the power supply. Combinations of states
indicated by the Okay and Fault LEDs indicate the status for the module as shown in the following table.
StatusFAIL or FAIL/ID
LED
OK LED
Power supply is on and outputting power to the switch.OffGreen
Power supply is connected to a power source but not outputting power to
the switch. The power supply may not be properly installed in the chassis.
OffFlashing
green
Either all the installed power supplies are not receiving power or an
uninstalled power supply is not receiving power.
OffOff
Cisco Nexus 9364C-H1 NX-OS Mode Switch Hardware Installation Guide