Fan modules (four) with the following airflow choices:
Port-side exhaust fan module with blue coloring (NXASFAN-160CFM-2PE)
Port-side intake fan module with burgundy coloring (NXASFAN-160CFM-2PI)
Table 1: Fan Speeds for this Switch
Port-Side Exhaust
Fan Speed %
Port-Side Intake
Fan Speed %
45%45%Typical/Minimum
80%80%Maximum
Note
When more than one Fan module (two rotors) fails, major alarm is raised
anda graceful shut down is performed within two minutes, unless the Fan
module is restored.
The switch functions normally when only one fan tray fails. If more than
onefan tray fails, the switch issues a warning and powers down within two
minutes.
Note
Power supply modules (two—one for operations and one for redundancy [1+1]) with the following
choices:
1400-W port-side exhaust AC power supply with blue coloring (NXA-PAC-1400W-PE)
1400-W port-side intake AC power supply with burgundy coloring (NXA-PAC-1400W-PI)
2000-W- HVAC/HVDC DC airflow power intake with burgundy coloring (NXA-PHV-2KW-PI)
2000-W port-side exhaust DC power supply with blue coloring (NXA-PDC-2KW-PE)
2000-W port-side intake DC power supply with burgundy coloring (NXA-PDC-2KW-PI)
Both the power supplies should be the same type. A mix of AC, DC, or
HVAC/HVDC power supplies in the same switch are supported for hot
swapping purposes within a time limit of 15 minutes.
All the fan modules and power supplies must use the same airflow direction.
Note
The following figure shows the switch features on the port side of the chassis.
Cisco Nexus 9364C-H1 NX-OS Mode Switch Hardware Installation Guide
2