EasyManuals Logo
Home>Cisco>Server>UCS C220

Cisco UCS C220 Installation And Service Guide

Cisco UCS C220
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #114 background imageLoading...
Page #114 background image
C-6
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Appendix C RAID Controller Considerations
RAID Controller Migration
RAID Controller Migration
This server supports hardware RAID (mezzanine and PCIe controller cards) and embedded software
RAID. See Table C-5 for which migrations are allowed and a summary of migration steps.
Ta b l e C-5 RAID Controller Migration
Starting RAID Controller Migrate to HW RAID Allowed? Migrate to SW RAID Allowed?
None (no drives)
Onboard SCU Storage
supp
ort is Disabled in BIOS
Allowed
1. Install card.
2. Install cables.
Allowed
1. Install desired upgrade
modules to motherboard.
2. Enable SCU storage support
in BIOS.
3. Install cables.
Embedded SW RAID
Onboard SCU Storage
supp
ort is Enabled in BIOS
Caution Data migration from
SW RAID to HW RAID
is not supp
orted and
could result in data loss.
Allowed only before there is data
on the drives; data migration is not
supported.
1. Disable SCU storage support
in BIOS.
2. Install card.
3. Install cables.
Not applicable
HW RAID
Onboard SCU Storage
supp
ort is Disabled in BIOS
Not applicable Not allowed

Table of Contents

Other manuals for Cisco UCS C220

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 and is the answer not in the manual?

Cisco UCS C220 Specifications

General IconGeneral
BrandCisco
ModelUCS C220
CategoryServer
LanguageEnglish