Intruder alarm system
Operating
Instructions
Servicing organisation details
Servicing organisation (Installer) name: ____________________________________
Telephone number: _____________________________________________________
Date of installation: _____________________________________________________
Account number: _______________________________________________________
1
0123
5678
Chime Omit
Reset
4
9
Set
Prog
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
Tamper
Attack
Day Power
PA
XR2/
XR2+
Intelligent Security & Fire Ltd
Question and Answer IconNeed help?

Do you have a question about the Citadel XR2 and is the answer not in the manual?

Citadel XR2 Specifications

General IconGeneral
BrandCitadel
ModelXR2
CategorySecurity System
LanguageEnglish

Summary

System Setup and Basic Operation

Using System Codes

Explains the 4-digit code for system operation and default settings.

Personal Attack Activation

How to activate the alarm system for personal attack.

System Features and Alerts

Fire Zone Alarms

Procedure for fire alarms, including sounds and actions.

How to Set the System

Entering Code and Checking Status

Enter code and verify the green Day indicator is lit.

How to Unset the System

Keying in Code to Unset

Key in code to stop entry tone; check for Day indicator light.

Investigating Alarm Events

If indicators are lit, seek assistance before investigating intrusion.

How to Part Set the System

Initiating Part Set Procedure

Enter code and listen for exit beeps to start the process.

Selecting Part Set Program

Press Prog and select program 2 or 3 for part-set operation.

How to Silence an Alarm

Stopping the Alarm Sound

Enter your code to stop the alarm sound and external siren.

Identifying Alarm Cause

Zone, Tamper, or Attack indicators show the cause of the alarm.

Cancelling Police Response

Contact installer for details on cancelling police response.

How to Reset After An Alarm

Performing a Standard Reset

Press the Reset key and check indicators for system reset.

Handling Fault-Lockout

Contact installer if system enters fault-lockout.

Anti Code Reset Procedure

Use a 6-digit anti-code provided by the installer to reset the system.

How to Omit Zones

Initiating Omit Procedure

Key in code to start the exit procedure for omitting zones.

Selecting Zones to Omit

Press Omit, then zone numbers to be omitted; indicators will flash.

How to Quick Set the System

Initiating Quick Set Procedure

Key in code to start the exit procedure; exit beep tone will start.

How to Change User Code

How to Change Second User Code

How to Change the Duress Code

How to Test Alarm System