Citrix ADC MPX
Health
attributes/-
Platform
SNMP Alarm
Support
MPX
5500/5600
MPX
7500/9500
MPX
9700/10500/12500/15500
MPX
9700/10500/
12500/15500
10G
+5.0 V Supply
(Volts)
No 4.8–5.2 4.8–5.2 4.8–5.2 4.8–5.2
+12.0 V
Supply (Volts)
No 11.5–12.35 11.52–12.35 11.5–12.31 11.8–12.35
-12.0 V Supply
(Volts)
No - NA - - NA - - NA - - NA -
Battery
(Volts)
No 3–3.5 2.85–3.5 2.85–3.5 2.85–3.5
Intel CPU Vtt
Power (Volts)
No 1–1.2 1–1.2 1–1.2 1–1.2
5 V Standby
(Volts)
No 4.9–5.2 4.9–5.2 4.9–5.2 4.9–5.2
Voltage Sen-
sor2(Volts)
No 1.2–2 1.2–2 1.2–2 1–1.8
CPU Fan 0
Speed (RPM)
Yes 3000–16000 3000–16000 3000–10000 3000–16000
CPU Fan 1
Speed (RPM)
Yes 3000–16000 3000–16000 3000–16000 3000–16000
System Fan
Speed (RPM)
Yes
900–15000 900–13000 900–10000 900–9000
System Fan 1
Speed (RPM)
No 900–15000 900–15000 900–10000 900–8000
System Fan 2
Speed (RPM)
No 900–15000 900–15000 900–10000 900–10000
CPU 1
Temperature
Yes 24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
CPU 0
Temperature
Yes 24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
© 19992022 Citrix Systems, Inc. All rights reserved. 195

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 5900 and is the answer not in the manual?

Citrix ADC MPX 5900 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 5900
CategoryNetwork Hardware
LanguageEnglish

Related product manuals