FILOX WS ISS1 \page 22
F i l o x S e r i e s F i l t e r
Installation Operation Maintenance Manual
11.0 TECHNICAL DATA
11.1 PROCESS AND OPERATING DATA
11.1.1 FILOX CF1054 TO CF1354
Model CF 1044 CF1248 CF1354
Parameter Units
Flow Rate M3/hr 0.9 1.35 1.8
Backwash Flow M3/hr 1.8 2.6 3.0
Regeneration
Time
Mins 20 20 20
Max. Operating
Temperature
Degrees
C
45 45 45
11.1.2 FILOX CF1465 TO CF 1865
Model CF 1465 CF1665 CF1865
Parameter Units
Flow Rate M3/hr 2.3 3.65 4.5
Backwash Flow M3/hr 3.5 4.6 5.7
Regeneration
Time
Mins 20 20 20
Max. Operating
Temperature
Degrees
C
45 45 45
11.1.3 FILOX CF 2160 TO CF 3072
Model CF 2160 CF2469 CF3072
Parameter Units
Flow Rate M3/hr 6.4 9.0 15.0
Backwash Flow M3/hr 7.9 12.1 17
Regeneration
Time
Mins 20 20 20
Max. Operating
Temperature
Degrees
C
45 45 45