8-22 Lift Truck Maintenance
Electric Truck Battery Maintenance
Battery charging installations must be located in areas designated for
that purpose. These areas must be kept free of all non-essential
combustible materials.
Facilities must be provided for:
Flushing spilled electrolyte
Eye wash facility
Fire protection
Protecting charging apparatus from damage by trucks
Adequate ventilation for dispersal of fumes from gassing
batteries.
When handling acid concentrates greater than 50 percent acid
(above 1.400 specific gravity), an eye wash fountain must be
provided.
A conveyor, overhead hoist, or equivalent material handling
equipment must be provided for handling batteries.
IMPORTANT
Electric truck batteries are heavy and awkward to handle.
They are filled with a very hazardous chemical solution.
On charge, they give off hydrogen and oxygen which, in
certain concentrations, are explosive. And they are costly.
Before you remove, service, or install a truck battery,
carefully read the following recommendations and in-
structions.
NO
SMOKING
BATTERY
SERVICE
AREA
NO
SMOKING
BATTERY
SERVICE
AREA