14
6. Wipe the collecting container with a
damp cloth if necessary and then dry
it or allow it to dry in the air. Never
assemble wet or damp components!
7. Once all components are dry, insert the
EPA11 filter into the collecting container
and place it back on the motor unit.
Itmust engage audibly.
8. Remove hair and fluff from the used
accessory.
9. Store the device and accessories in a
cool, dry place which is protected from
direct sunlight and is out of the reach
ofchildren and animals.
L
To prevent a deep discharge of the
battery, charge it up every 3months
if it is not used for a prolonged
period.
TROUBLESHOOTING
If the device does not work properly, check whether you are able to rectify the problem
yourself. If the problem cannot be solved with the steps below, contact the customer service
department.
Do not attempt to repair an electrical device yourself!
The battery is not charging. The
control lampdoes not light up.
The USB cable(6) is not connected correctly
to the device or the USB mains adapter.
► Check the connection and correct it.
The USB mains adapter is not inserted in the
plug socket correctly.
► Correct the fit.
The plug socket is defective.
► Try another plug socket.
The device does not start.
The battery is empty.
► Charge up the battery.
Low suction force.
The battery is weak.
► Charge up the battery.
The collecting container(8) is too full.
► Empty the collecting container.
The EPA11 filter(10) is dirty.
► Clean the filter.
The suction opening(9) or the crevice
nozzle(7) is blocked.
► Switch off the device and remove the
blockage.
The dirt particles are too large or too heavy.
► Switch off the device and remove dirt
particles by hand.
Unusual odour
The device is being used for the first time.
► A new odour is normal when the device
is used for the first time; it disappears
after a while.