34
CORRESPON-
DING DTMF
CHARACTER
COMMANDS
ITEM COMMAND EXAMPLE & USAGE DEFAULT
20#
Reporting
method for
all 4
Telephone
numbers
FMATG
PROG 1111 FMATG:0
To set the reporting methods for all 4 Telephone numbers
0=Contact ID, 1=Scancom, 2=Tunstall, 3=Speech,
4=SMS CID
0 =
Contact ID
21#
Reporting
method for
Telephone
number 1
FMAT1
PROG 1111 FMAT1:0
To set the reporting method for Telephone number 1
0=Contact ID, 1=Scancom, 2=Tunstall, 3=Speech,
4=SMS CID
0 =
Contact ID
22#
Reporting
method for
Telephone
number 2
FMAT2
PROG 1111 FMAT2:0
To set the reporting method for Telephone number 2
0=Contact ID, 1=Scancom, 2=Tunstall, 3=Speech
4=SMS CID
0 =
Contact ID
23#
Reporting
method for
Telephone
number 3
FMAT3
PROG 1111 FMAT3:0
To set the reporting method for Telephone number 3
0=Contact ID, 1=Scancom, 2=Tunstall, 3=Speech
4=SMS CID
0 =
Contact ID
24#
Reporting
method for
Telephone
number 4
FMAT4
PROG 1111 FMAT4:0
To set the reporting method for Telephone number 4
0=Contact ID, 1=Scancom, 2=Tunstall, 3=Speech
4=SMS CID
0 =
Contact ID
31#
Ringer
enable for
incoming
calls
ENRIN
PROG 1111 ENRIN:0
To enable/disable ring tone for incoming calls
0=Disable, 1=Enable
0 = Disable
32#
Audible
fault alert
FAUTA
PROG 1111 FAUTA:0
To enable/disable audible fault alert
0=Disable, 1=Enable
0 = Disable
33#
Help arrived
signalling
HELPA
PROG 1111 HELPA:0
To enable/disable help arrived signalling
0=Disable, 1=Enable
0 = Disable
34#
Emergency
button
EMBUT
PROG 1111 EMBUT:1
To enable/disable the Emergency button to send an
emergency alarm report
0=Disable, 1=Enable
1 = Enable
35# Silent mode SILMO
PROG 1111 SILMO:1
To enable/disable silent mode
0=Silent mode On, 1=Silent mode Off
1 = Silent
mode Off
37#
AC fault
report
ACRPT
PROG 1111 ACRPT:1
To enable/disable AC fault report
0=Disable, 1=Enable
1 = Enable
38#
Follow-On &
Call Back
FOLON
PROG 1111 FOLON:0
To set the follow-on & call back mode
0=Follow-on, 1=Call-back, 2=Follow-on & Call-back
0 = Follow-
on
40#
Set access
code
ACCES
PROG 1111 ACCES:1234
To change the access code for installer (4-digit)
1111
42#
Guard time
delay
GUDTI
PROG 1111 GUDTI:10
To set the guard time delay time for a compatible sensor
(except Fall Sensor)
00=Instant, 01-99=1-99 seconds
00= instant
reporting
10=10
seconds
43#
Periodic
test call
TESTC
PROG 1111 TESTC:0
To set the periodic test call
0=Off, 1=1 Day, 2=2 Days, 3=3 Days, 4=4 Days
5=5 Days, 6=6 Days, 7=7 Days ,8=30 Days
0 = Off
44#
Mobility
timer
MOBTI
PROG 1111 MOBTI:00
To set the Mobility timer
00=Disable, 01~36 =1 ~ 36 Hours
00 =
Disable
45#
Follow-on
choice
LFOLL
PROG 1111 LFOLL:2
To set the follow-on choice for digital reporting
0=Wait command, 1=Listen
2=Two-way voice communication
2 =
Two-way
voice
comm.