Excellence
SIZE 80.3 90.4 100.4 110.4 120.4 130.4 145.4 160.4 185.5 210.6 225.6 240.6
Compressor
Type of compressors 1 SCROLL
Refrigerant R-32
No. of compressors [Nr] 3 4 4 4 4 4 4 4 5 6 6 6
Rated power (C1) [HP] 40 40 50 50 60 65 65 80 80 105 105 120
Rated power (C2) [HP] 40 50 50 60 60 65 80 80 105 105 120 120
Std Capacity control steps 4 6 4 6 6 6 6 4 6 8 8 6
Oil charge (C1) [l] 9 9 10 10 12 12 12 15 15 25 25 23
Oil charge(C2) [l] 7 10 10 12 12 12 15 15 25 25 23 23
Refrigerant charge (C1) [Kg] 20 34 34 34 35 45 46 47 57 58 66 68
Refrigerant charge (C2) [Kg] 19 33 33 34 35 44 45 48 57 57 67 69
Refrigeration circuits [Nr] 2
Internal exchanger
Type of internal exchanger 2 PHE
N. of internal exchanger [Nr] 1
Water content [l] 19 19 20 24 28 32 36 48 57 57 49 60
Minimum system water content [l] 1350 1500 2700 2700 2700 2150 2350 4350 3150 3450 3750 4500
External exchanger
Type of external exchanger 3 CCHY
Number of coils [Nr] 4 4 4 4 4 4 4 4 4 4 4 4
External Section Fans
Type of fans 4 AX
Number of fans [Nr] 4 6 6 6 6 8 8 8 10 10 12 12
Type of motor 5 EC
Standard airflow (ST/SC) [l/s] 24000 36000 36000 36000 36000 48000 48000 48000 60000 60000 72000 72000
Standard airflow (EN) [l/s] 17933 26900 26900 26900 26900 35867 35867 35867 44833 44833 53800 53800
Connections
Water fittings 4" 4" 4" 4" 4" 5" 5" 5" 5" 5" 5" 5"
Power supply
Standard power supply 400/3~/50
Electrical data
F.L.A. - Total [A] 158,2 165,2 194,8 213,5 232,2 256,4 282,3 310,2 359,8 405,6 437,4 465,2
F.L.I. - Total
[A] 96,3 98,1 117,9 130,7 143,5 158,5 175,6 194,0 224,1 251,7 272,6 291,0
M.I.C. - Value 6 [A] 566,2 406,9 436,5 547,9 566,6 590,7 616,6 718,2 694,2 740,0 771,7 799,6
M.I.C. - with soft start accessory 6 [A] 314,5 290,2 379,0 406,9 425,6 440,5 438,6 466,5 516,2 562,0 593,7 621,6
Construction
1. SCROLL = SCROLL Compressor
2. PHE = Plate exchanger
3. CCHY = Copper / aluminium condenser coil with hydrophilic treatment
4. AX = Axial fan
5. EC = Asynchronous motor with permanent magnet commuted electronically.
6. M.I.C.=Maximum unit starting current. The M.I.C. value is obtained adding the max. compressor starting current of the highest size to the power input at max. admissible condi-
tions (F.L.A.) of the remaining electric components.
Unbalance between phase max 2 %
Voltage variation: max +/- 10%
Electrical data refer to standard units; according to the installed accessories, the data can suer some variations.