5.2. Machine connection to power supply.
Machine connection to power supply need to be carry out by flexible hose 5x2,5mm². In
electrical switchboard appoint a separate box with protection 25 A.
Check if mixing shaft rotation is in conformity with markings on control panel. In case of
disagreement, switch two phases connected to the power supply box.
ATTENTION!
Check the effectiveness of zeroing by measurement of resistance in
connections in reset circuit. It can not be higher than 0,1Ώ in any section and
should be documented. Work in the electrical system may perform only
electrician with the appropriate qualifications and licenses.
6. Daily maintenance.
At the first startup of the day, must check the effectiveness of safety and protective devices.
The checking refers to:
Control of action of tank top cover switch, mixing paddles can not work while cover is
open.
Control of action of stuffing ejection cover switch, mixing paddles can not work while
stuffing trolley is absent
Control of action of chamber drive shaft door switch, with the door open can not start
the machine (works as emergency button)
Control of action of the emergency button ( red „mushroom” button with a yellow ring
on the side of the control panel). After pressing the emergency button, all drives are
switched off. Emergency button when pressed, meshes and can be unlocked by
pulling the „mushroom”. Emergency button works only in terms of the control voltage,
it doesn't turn off the main circuit.
Control of action of the main switch. After turning the knob from "I" in "0" position, the
machine power supply will be cut off.
ATTENTION!
When safety or protective devices fault occurs, do not use the machine. The
defect should be removed by a specialized service. Any changes in safety
devices are not allowed. Possible changes relieve the manufacturer of
responsibility and guarantee obligation.
7. Operation
Paddle mixer RX-600 is equipped with a control panel, described in section 3.4. It controls
the mixing process. It allows you to select the direction of convergent and divergent rotations,
setting speed of paddle mixers, stop the mixer.