CMR Surgical Ltd
1 Evolution Business Park
Milton Road, Cambridge CB24 9NG, UK
Versius Surgical System
Electrosurgery Instrument Cables Reprocessing Instructions (Version 2.0)
REF 70300
Read before use

Other manuals for CMR versius

Question and Answer IconNeed help?

Do you have a question about the CMR versius and is the answer not in the manual?

CMR versius Specifications

General IconGeneral
BrandCMR
Modelversius
CategoryCables and connectors
LanguageEnglish

Summary

Introduction to Versius Surgical System

Warning, Precaution, and Information Symbols

Explains warning, precaution, and information symbols used in the manual for clarity and safety.

Electrosurgery Instrument Cables Description

Details the types and connectors of Versius electrosurgery instrument cables.

Receiving New Instrument Cables

Instructions for receiving new electrosurgery instrument cables, noting they are supplied non-sterile.

Transport and Storage Guidelines

Provides guidance on how to transport and store cables to prevent damage.

Repair Policy

Advises against attempting to repair or modify cables and directs to customer services.

Disposal Procedure

Instructs users to return cables to CMR Surgical for disposal.

Reprocessing Versius Electrosurgery Instrument Cables

Reprocessing Procedures Overview

Outlines the sequence of procedures for reprocessing electrosurgery instrument cables.

Point-of-Use Preparation

Details the initial steps to take immediately after use to prepare cables for reprocessing.

Initial Manual Cleaning

Provides step-by-step instructions for manually cleaning the instrument cables.

Full Manual Cleaning

Detailed instructions for performing the full manual cleaning process for cables.

Automated Cleaning and Thermal Disinfection

Instructions for using automated equipment for cleaning and thermal disinfection.

Preparation for Sterilisation

Steps required to prepare the cables for the sterilization process.

Sterilisation Process

Details the procedure for steam sterilisation of the instrument cables.

Appendix A: Versius Electrosurgery Instrument Cables

Maximum Reprocessing Cycles for Cables

Lists the maximum number of reprocessing cycles allowed for each cable type.

Appendix B: Validated Equipment and Parameters

Validated Equipment and Parameters

Specifies validated equipment and parameter settings for automated cleaning and sterilization.