Quick Start Guide
T-Rex Series
CNC-STEP e.K. Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 8
Support: +49 (0)2831/91021-50
15.01.2015
Noga-Minimalmengenschmierung
1.4 Noga Minimum lubrication system
The Noga minimal lubrication system allows the processing of materials which make cooling
necessary. For the operation of a compressor is required with min. 2.5 bar.
1 – Coolant container 2 – control valve
3 – Air connection Z axis 4 – adjustable nozzle
5 – Manual On / Off (with the hex screw you can adjust the amount of air)
1.4.1 control box with solenoid valve
The control box for the Noga system is located on the back of the machine. The system is
automatically switched on and off via software, when connected to the Zero-3 Control.
1 – 230V power supply (at Rel.2 of Zero-3)
2 – Air output to Z axis
3 - silencer
4 – Air connection (min. 2.5 bar)