15
ENGLISH
Troubleshooting guide
Thedehumidifier
will not switch on.
Make sure that themains lead is properly plugged in and that there
is power in thewall socket.
Thewater reservoir is full or incorrectly fitted.
Theset humidity level has been reached.
Thehumidity is
not reducing.
Thedehumidifier has not been used long enough.
Make sure that nothing is preventing theair in theroom where
thedehumidifier is used from circulating properly.
Thehumidity level is not set low enough.
Make sure that no outdoor air can enter theroom in which
thedehumidifier is being used.
Theambient temperature is below 15 ºC.
Is there aheat source in theroom which is raising thehumidity?
Unusual noises
emitted during use.
Make sure that theair filter is clean.
Thedehumidifier is tilted or standing on anuneven surface.
Error and protection
codes (shown on
thedehumidifier’s
display)
AS: Defective humidity sensor. Turn off theair conditioner, pull out
theplug and plug it in again. If this does not solve theproblem,
contact aqualified service centre.
ES: Defective temperature sensor. Turn off theair conditioner,
pull out theplug and plug it in again. If this does not solve
theproblem, contact aqualified service centre.
P1: Automatic defrosting in progress. Let thedehumidifier be switched
on until P1 no longer appears on thedisplay.
P2: Thewater reservoir is full or incorrectly fitted. Empty of refit it.
E3: Other defects. Turn off theair conditioner, pull out theplug
and plug it in again. If this does not solve theproblem, contact
aqualified service centre.
Responsible disposal
This symbol indicates that this product should not be disposed of with general
household waste. This applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards caused by incorrect waste
disposal, theproduct must be handed in for recycling so that thematerial can
be disposed of in aresponsible manner. When recycling your product, take it to
your local collection facility or contact theplace of purchase. They will ensure that
theproduct is disposed of in anenvironmentally sound manner.
Specifications
Power supply 220–240 V, 50 Hz
Power 415 W
Dehumidification capacity Up to 20 l/day
Reservoir capacity 3 l
Operating temperature 5– 35 ºC
Coolant R290
Size 51×35×21 cm
Weight 13 kg