3
Part 2 Specifications
The CR6 Oven is a 490mm (internal) full width oven
fitted with French style opening doors. The oven
burner is a 24-26 MJ oven burner and has pilot and
flame failure with piezo ignition.
The CR9 Oven is a 780mm (internal) full width oven
fitted with French style opening doors. The oven
burner is a 28-30 MJ oven burner and has pilot and
flame failure with piezo ignition.
The Range has an easy clean stainless steel external
finish.
Model Covered in this Specification -
CR6D[1] Range 4 Open Burners.
CR6C[1] Range 2 Burners + 300mm Griddle.
CR6B Range 600mm Griddle.
CR9D[1] Range 6 Open Burners.
CR9C[1] Range 4 Burners + 300mm Griddle.
CR9B[1] Range 2 Burners + 600mm Griddle.
CR9A Range 900mm Griddle.
[1] - Open Burner Options;
F - With Flame Failure Protection.
- Standard Burners.
General
A heavy duty, general purpose gas range created
for compact modular kitchens and available in a
600mm and 900mm wide option. It has a high
option Cooktop / Griddle arrangement and is
available on adjustable front feet and robust rear
rollers. Open Burners have Flame Failure Option as
standard for UK market and as an option for all oth-
er markets.
Griddles are available in 300mm, 600mm and for
the CR9 Gas Static Oven Range, 900mm options
and are fitted with pilot, flame failure and piezo
ignition as standard.
Gas Supply Requirements
- Australia:
- New Zealand:
NOTE:
(
*
) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart
from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’ Section for further details).
Natural Gas LP Gas (Propane)
Open Burner
(each)
Griddle
(each 300mm
section)
Oven Open Burner
(each)
Griddle
(each 300mm
section)
Oven
CR6 CR9 CR6 CR9
Input Rate (N.H.G.C.)
22 MJ/hr 20 MJ/hr 24 MJ/hr 28 MJ/hr 22 MJ/hr 20 MJ/hr 24 MJ/hr 28 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating
Pressure (*)
1.0 kPa (*) 2.6 kPa (*)
Gas Connection
¾” BSP Male
Natural Gas LP Gas
Open Burner
(each)
Griddle
(each 300mm
section)
Oven Open Burner
(each)
Griddle
(each 300mm
section)
Oven
CR6 CR9 CR6 CR9
Input Rate (N.H.G.C.)
22 MJ/hr 20 MJ/hr 24 MJ/hr 28 MJ/hr 22 MJ/hr 20 MJ/hr 24 MJ/hr 28 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating
Pressure (*)
1.0 kPa (*) 2.6 kPa (*)
Gas Connection
¾” BSP Male