2.) For all Euro Tone Programming, refererence Chart 1 on Page 13.
3.) A.) Pressing the Secondary (SEC) button once will light up the button. This is enabling
that “multiplier”. If the Secondary (SEC) button is pressed again, the button backlighting will
turn OFF and disable that “multiplier”.
B.) Pressing the Repeat (▲) button once will light up the button. This is enabling that
“multiplier”. If the Repeat (▲) button is pressed again, the button backlighting will turn OFF
and disable that “multiplier”.
C.) Pressing Secondary (SEC) once and Repeat (▲) once will light up both buttons. This is
enabling that ”multiplier”. If both buttons are pressed again, their backlighting will turn off
and disable that “multiplier”.
D.) After the multiplier(s) is chosen, use the ◄ and ► to navigate the lights in the yellow
bargraph area of the control head to choose the tone that is desired. After tone selected,
pressing Alt will save the selection & continue to next step in programming.
ALT Will advance the programming mode to next step.
PROGRAMMING STEP #6:
ENABLES PROGRAMMING OF THE LIGHT key:
the following keys will be illuminated:
RADIO (will be illuminated Indicating Step #6 in Pressing any key
along with other any programming mode. while in the LIGHT
other keys programmed programming mode
into the light list.) will include that key
function in the list
of functions for the
EMERGENCY key.
Headlight Flasher:
If the vehicle is equiped with a headlight asher, pressing both the left and right arrow keys
at the same time will enable this function when the EMERGENCY key is selected and will
illuminate the ALT key to indicate such.
Intersection Lights:
If the vehicle is equipped with intersection lights, pressing both the SEC & TAKEDOWN keys
at the same time will enable this function when the EMERGENCY key is selected.
(No indication is displayed for this function.)
ALT Will advance the programming mode to next step.
T56095 Rev. A Page 17 of 22