Code Blue
259 Hedcor Street
Holland, MI 49423 USA
800.205.7186
www.codeblue.com
GU-145-Bpage 17 of 19
IA3100
Administrator Guide
How do I program the IA3100 to work on a ring-down line?
Call into the Code Blue unit’s phone number and enter program mode 2<password>#. Key in 354#.
This will set the IA3100 to operate in ring-down mode. Press and hold # down for two seconds to
exit program mode.
How do I resolve a IA3100 that appears to be locked up?
Try to reset or re-energize the circuit by disconnecting the 14-pin green Phoenix connector AND
the gray ribbon cable for a couple of seconds. Plug cables back in and test the unit. Check and
make sure the operating voltage at the unit is between 12-24V AC/DC. An overvoltage condition
for a period of time may cause the regulator to overheat and the speakerphone to go into a thermal
shutdown.
Where can I nd speakerphone programming manuals?