Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-145-Epage 15 of 23
IA3100
Administrator Guide
54 Second phone number for “Info” or “Call”
button
54<<2
nd
Information number>>#
Up to 16 digits
=2-second pause
54
Veries the second Information/Call number
54<<2
nd
Information
number>>#
Triple beep = rejected
Single beep = OK
55 Veries the third Information/Call number 55<<3
rd
Information number>>#
Up to 16 digits
=2-second pause
55
Veries the third Information/Call number
55<<3
rd
Information
number>>#
Triple beep = rejected
Single beep = OK
57 Assign progress tone table to each of the
phone numbers. The IA3100 recognizes the four
different tone tables.
57<<abcdefg>># / Default =
1111111
a = 1
st
Emergency (cmd. 50)
b = 2
nd
Emergency (cmd. 51)
c = 3
rd
Emergency (cmd. 52)
d = 1
st
Information (cmd. 53)
e = 2
nd
Information (cmd. 54)
f = 3
rd
Information (cmd. 55)
g = Power loss warning (cmd.
59)
58 Cycle count – Number of cycles for the
programmed numbers to repeat. (1-3)
58<<Cycle count>># / Default
= 2
59 Power loss phone number – This is a number
that will be called when the IA3100 has lost power
for 15 minutes. This feature is best used when it
has been programmed to dial a specic display
phone.
59<<power loss number>>#
Up to 16 digits
60 Unique ID number – This number is sent with
the ANI to identify the unit and is required with the
Code Blue software. (Also see command 65)
60<<ID number>>#
Up to 16 digits
60
Veries the Unique ID number
60<<ID number>>#
Triple beep = rejected
Single beep = OK
61
Programming password (command 61 must
follow immediately after command 61)
61<<new program password>>#
Default = 2258
61
Veries the new programming password – This
action can only be used during this programming
instance, meaning if you log out of programming
and return to the programming sequence to
verify the password you will not receive a OK
conrmation tone.
61<<new program
password>>#
Triple beep = rejected
Single beep = OK
62 Monitoring password (command 62
must
follow immediately after command 62)
62<<new monitor password>>#
Default = 2258
62
Veries the new monitoring password – Same
conditions apply as stated in 61*
62<<new monitor
password>>#
Triple beep = rejected
Single beep = OK
(Continued on next page)
Line Ring Back (Seconds) Busy Tones
(Seconds)
Recorder Tone
1 2 On, 4 OFF ½ ON, ½ OFF ¼ ON, ¼ OFF
2 ½ ON, ¼ OFF, ½ ON, 4 OFF ½ ON, ½ OFF ¼ ON, ¼ OFF
3 ½ ON, ½ OFF, ½ ON, 2½ OFF ½ ON, ½ OFF ¼ ON, ¼ OFF
4 1 ON, 3 OFF ½ ON, ½ OFF ¼ ON, ¼ OFF