91 Data Input – This command enables and disables
the RS485 Data input to initiate an Emergency
Call.
91<<mode>># / Default = 1
0 = Disabled
1 = Enabled
92 Partial Reset to default – Returns all commands
to their defaults with the exception of stored phone
numbers, passwords, tone tables, and voice
recordings.
92#
93 Diagnostic Routine – This can be used to verify
that the speakerphone is functioning correctly.
This command will cause the IA100 to hang up
and perform a self check. When the self check
is complete, the IA3100 will call the “Call Back
Number” and report with either a single tone for a
failure or a double tone for a pass.
93<<Call Back Number>>#
# Hang up - forced # = forced hang up