Troubleshooting
Created by EBCCW 00:06
27
5815EN-03
4 Troubleshooting
Jerky running
Drive unit is running, conveyor chain is not
Motor overheating on drive unit
Cause Corrective action
Damaged or badly fit-
ted slide rail
Inspect and replace if nec-
essary.
Wrongly adjusted
slip clutch
Check and adjust slip
clutch.
Worn transmission
parts
Check/replace transmis-
sion chain, chain drive
sprocket.
Conveyor chain is too
tight/loose
Tension conveyor chain
correctly.
Dirty conveyor Clean conveyor chain/
slide rail. Lubricate with
silicone based lubricant.
Cause Corrective action
Wrongly adjusted
slip clutch
Check adjustment of slip
clutch.
Friction discs in slip
clutch are worn or
contaminated
Check and replace if nec-
essary.
Damaged/badly fit-
ted slide rail
Check the free running of
the conveyor chain.
Transmission prod-
ucts are not fitted
Check and fit.
Cause Corrective action
Overloaded conveyor Remove products from
conveyor and test run.
Check actual conveyor
load against recom
-
mended loading.
Gearbox leaking oil Check output shaft seal
and area around motor/
gearbox interface.
Dirty conveyor Clean the conveyor chain
with warm water (50°).