ORIGINAL LINE A
29
Original instructions.
POSSIBLE SOLUTION
Fault and solution
FAULT POSSIBLE SOLUTION
Power switch does not lit
Check plug connection to wall socket.
Check fuse in plug.
Check if hot plate becomes warm, if so
replace power switch.
Hot plate does not become
warm although switch is lit.
Check connection to hot plate.
If hot plate is defective, replace.
Brewer excess steam.
Machine may require descaling.
Spray nozzel may need unblocking.
Hose may be bent.
Inlet to boiler may be blocked. Descale
machine - if boiler still defective - replace.
Machine will not brew.
Check overheating protection.
Check microswicth.
Check connection to boiler.
Boiler unit may need replacing.
The machine does not take
in water
Make sure water tap is open.
Make sure the water hose is not bent.
Check inlet valve.
Check that the display is blinking.
The machines does not
stop taking in water.
Dirt in the inlet valve.
inlet valve is defective - replace
PCB is defective - replace
The machine is giving
wrong amount of water.
Check water tap.
Water hose is bent.
Dirt in inlet valve.
Water amount adjustment set in display is
adjusted faulty. Adjust according to page 21.
Defect oatregulator in inlet valve - replace