The appliance is to be installed in accordance with the Safety
WARNING: Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.The appliance shall be stored
in a room without continuously operating ignition sources(forexample: open flames,
an operating gas appliance or an operating electric heater.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Warning: The appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation;
Warning: The appliance shall be stored in a room without continuously operating
open flames (for example an operating gas appliance) and ignition sources (for
example an operating electric heater).
Warning: The appliance shall be stored so as to prevent mechanical damage from
occurring
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges, or any other adverse environmental effects. The check shall
also take into account the effects of aging or continual vibration from sources such as
compressors or fans.
Before carrying out Decommissioning procedure, it is essential that the technician is
completely familiar with the equipment and all its detail. It is recommended good
practice that all refrigerants are recovered safely. Prior to the task being carried out,
an oil and refrigerant sample shall be taken in case analysis is required prior to re-
use of recovered refrigerant. It is essential that electrical power is available before
the task is commenced.
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely.
The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery of all
appropriate refrigerants including, when applicable, FLAMMABLE REFRIGERANTS
The recovered refrigerant shall be returned to the refrigerant supplier in the correct
recovery cylinder, and the relevant waste transfer note arranged. Do not mix
refrigerants in recovery units and especially not in cylinders
Details of Product
It uses quality, effective and hermetic compressor with broad range of starting
voltage, suitable ambient temperature: not higher than 38
/100°F,
reasonable matching of the freezer system guarantees its powerful
refrigerant ability and energy saving.
A good choice for storage of your variety of frozen food product. It is easy to lift up
the lid to get your frozen food and close the lid to seal the freezer in.
Caution for Using
1. Unpack all packages before using the freezer. Don’t bend it over more than 60°
while moving it.
2. The freezer should be installed in the environment of good ventilation, Cool and
dry and without corrosive gas. It should not be installed close to heat sources or
directly under the sunlight. The space more than 10cm between the wall of the
front and the back of the freezer should be allowed. When installing, the wheels

Related product manuals