EasyManuals Logo

coldline W14T User Manual

Default Icon
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Shortcut commands while in standby mode
1
Blast freezing
2
Start
Detailed commands sequence:
1. Make sure the appliance is in standby mode (6.1).
2. Insert the needle probe in the product to be chilled (10.0).
3. Press button to select the blast freezing cycle.
The led button comes on.
Display DY1 gives the setpoint of the air in the compartment (-38°C).
Display DY2 reads ---”.
4. Press button to start the blast freezing cycle.
The led button comes on.
The compressor only starts working 5 seconds after key is pressed (pump-down 6.4)
DY1 gives needle probe temperature, and DY2 the cycle time remaining, counting down from 240 minutes.
If you press button while the cycle is running, you can view the time elapsed since it started.
5. A buzzer sounds to advise that the blast chilling cycle has finished.
6. At the end of the cycle, holding mode starts and continues indefinitely at a holding temperature of -20°C.
The led button flashes.
If you press button during holding time, you can view the time of the cycle just completed to see how long
it took.
The holding stage must last only as long as strictly necessary.
7. To exit holding mode, press button .
The led button goes off.
The compressor stops 5 seconds after button is pressed (pump-down 6.4).
Important
Countdown starts when core temperature measured by the needle probe drops below +65°C.
When a blast freezing cycle is started, the compressor works non-stop until air temperature in the
compartment reaches -38°C. After this, it can cycle on and off to keep this temperature constant.
The blast freezing cycle ends when the product's core temperature measured by the needle probe reaches -18°C. The
cycle cannot last more than 240 minutes.
8.0 TIME-BASED BLAST CHILLING/BLAST FREEZING
Italiano
English
Deutsch
Français
8.1 TIME-BASED SOFT BLAST CHILLING
The time-based soft blast chilling cycle is controlled by the timer.
Shortcut commands while in standby mode
1
2
3
Soft blast chilling
Time-based cycle
Detailed commands sequence:
1. Make sure the appliance is in standby mode (6.1).
2. Press button to select the soft blast chilling cycle.
The led button comes on.
Display DY1 gives the setpoint of the air in the compartment (-2°C).
Start
31