- At the end of each blast chilling/blast freezing cycle.
- At 6-hour intervals during holding.
The purpose of the evaporator sensor is to produce the utmost efficiency and shorten defrosting times by measuring the
end-of-defrosting temperature.
6.8 MANUAL DEFROSTING
This mode should be used only when further defrosting is required in addition to that performed
automatically by the appliance.
Shortcut commands while in standby mode
Make sure the appliance is working (6.1).
Hold button down for 5 seconds.
The led by the button comes on, and goes off when cycle ends.
The defrosting cycle stops automatically. How long it takes depends on how much frost there is on the evaporator
coil.
Once defrosting has finished, the appliance resumes normal operation.
7.0 TEMPERATURE-BASED BLAST CHILLING/BLAST FREEZING
7.1 TEMPERATURE-BASED SOFT BLAST CHILLING
The temperature-based soft blast chilling cycle is controlled by the needle probe.
Shortcut commands while in standby mode
Detailed commands sequence:
1. Make sure the appliance is in standby mode (6.1).
2. Insert the needle probe in the product to be chilled (10.0).
3. Press button to select the soft blast chilling cycle.
The led button comes on.
Display DY1 gives the setpoint of the air in the compartment (-2°C).
Display DY2 reads “---”.
4. Press button to start the soft blast chilling cycle.
The led button comes on.
The compressor only starts working 5 seconds after key is pressed (pump-down 6.4).
DY1 gives needle probe temperature, and DY2 the cycle time remaining, counting down from 90 minutes.
If you press button while the cycle is running, you can view the time elapsed since it started.
5. A buzzer sounds to advise that the blast chilling cycle has finished.
6. At the end of the cycle, holding mode starts and continues indefinitely at a holding temperature of +3°C.
The led button flashes.
If you press button during holding time, you can view the time of the cycle just completed to see how long
it took.
The holding stage must last only as long as strictly necessary.
7. To exit holding mode, press button .
The led button goes off.
The compressor stops 5 seconds after button is pressed (pump-down 6.4).
29