TECHNICAL GUIDE
Echelon
MODELS: FC9M*UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW MODULATING FURNACES
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
259720-CTG-B-0108
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
Provides increased comfort level & very quiet unit opera-
tion
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
Integrated control module for reliable, economical opera-
tion.
May be installed as either two-pipe (direct vent) or single
pipe vent (using indoor combustion air)
Top intake & vent connection allows installation in narrow
locations.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
No special vent termination kit required.
100% shut off main gas valve for extra safety.
PSC -four speed, direct drive motor with large, quiet
blower.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance or
service.
Protection from intake, exhaust or condensate blockage.
Insulated blower compartment for quiet operation.
Question and Answer IconNeed help?

Do you have a question about the Coleman FC9M120D20UP11 and is the answer not in the manual?

Coleman FC9M120D20UP11 Specifications

General IconGeneral
BrandColeman
Model NumberFC9M120D20UP11
CategoryFurnace
Fuel TypeNatural Gas
Heating Capacity120, 000 BTU
Input BTU120, 000 BTU
Efficiency Rating95%
Efficiency95% AFUE
Output BTU114000 BTU
Blower SpeedVariable
Warranty10-Year Limited Warranty

Summary

Product Description and Features

Product Description

Details the Category IV, highly efficient, high-temperature condensing type furnaces.

Warranty Information

Outlines the limited warranty terms for heat exchangers on heat-pump configurations.

Key Product Features

Lists specific operational features like modulating heating, induced draft, and integrated controls.

Physical Dimensions

Performance and Electrical Data

Electrical and Performance Specifications

Presents detailed electrical inputs, outputs, blower specs, and performance data for various models.

Important Notes and Guidelines

Provides critical operational notes, including altitude adjustments and air filter requirements.

AC 11A Wiring Diagram

Thermostat Chart for AC 11A

Illustrates thermostat connection for Single Stage Air Conditioner with PSC Modulating Furnace.

AC 11B Wiring Diagram

Thermostat Chart for AC 11B

Illustrates thermostat connection for Single Stage Air Conditioner with PSC Modulating Furnace.

AC 11C Wiring Diagram

Thermostat Chart for AC 11C

Illustrates thermostat connection for Single Stage Air Conditioner with PSC Modulating Furnace.

AC 11D Wiring Diagram

Thermostat Chart for AC 11D

Illustrates thermostat connection for Single Stage Air Conditioner with PSC Modulating Furnace.

HP 17A Wiring Diagram

Thermostat Chart for HP 17A

Illustrates thermostat connection for Single Stage Heat Pump with PSC Modulating Furnace.

Airflow Performance Data

Installation Clearances and Accessories

Unit Clearances to Combustibles

Specifies required clearances for the unit from combustible materials.

Available Unit Accessories

Lists optional accessories like LP conversion kits, vent terminations, and thermostats.