......................................... I-I ', H', ,'1.-ยข" 'l.I
HIGH EFFICIENCY
CLAM TUBE HEAT EXCHANGER SERIES
MODELS: UGAA/UGAB
(Single Stage Multi-Position)
75- 100 MBH INPUT
(21.98 - 29.31 KW) INPUT
!
ISO 9001
Certified Quality
Management System
LIST OF SECTIONS
SAFETY ................................................ 1 TWINNING AND STAGING ................................ 15
DUCTWORK ............................................ 4 VENT/COMBUSTION AIR SYSTEM ......................... 16
FILTERS .............................................. 10 SAFETY CONTROLS .................................... 22
GAS PIPING ........................................... 11 START-UP AND ADJUSTMENTS ........................... 22
ELECTRICAL POWER ................................... 13 WIRING DIAGRAM ...................................... 29
LIST OF FIGURES
Upflow/Horizontal Configuration .............................. 5
Downflow/Horizontal Configuration ........................... 5
Vent Blower ............................................. 6
Top Cap ................................................ 6
Dimensions ............................................. 7
Combustible Floor Base Accessory ........................... 8
Typical Attic Installation .................................... 9
Typical Suspended Furnace ! Crawl Space Installation ............ 9
Side Return Cutout Markings ............................... 10
Horizontal Mount and Filter ................................ 10
Downflow Filter .......................................... 10
Return Filter Grill and Return Duct Installation .................. 11
Gas Valve .............................................. 11
Upflow Configuration ..................................... 11
Downflow Configuration ................................... 12
Gas Piping ............................................. 12
Burner Assembly ........................................ 12
Electrical Wiring - Upflow Position ........................... 14
Single Stage Heat Thermostat Connections ................... 14
Accessory Connections ................................... 14
Typical Twinned Furnace Application ......................... 15
Single Stage Twinning Wiring Diagram ....................... 16
Two-Stage Twinning Wiring Diagram ......................... 16
Vent Termination ........................................ 16
Vent Termination ........................................ 17
Alternate Air Intake, Air Outlet and Chimney Connections ......... 17
Air Inlet, Outlet and Chimney Connections ..................... 17
Typical Sidewall Vent Application ............................ 18
Typical Sidewall Vent and Termination Configuration ............ 18
Typical Chimney Connections .............................. 18
Horizontal Air Inlet, Outlet and Chimney Connections ............ 18
Home Layout ........................................... 19
Combustion Airflow Path Through The Furnace
Casing to the Burner Box .................................. 20
Outside and Ambient Combustion Air ......................... 21
Pressure Switch Tubing Routing ............................ 22
Gas Valve .............................................. 25
Reading Gas Pressure .................................... 25
Furnace Control Board .................................... 26
Wiring Diagram .......................................... 29
LIST
Unit Clearances to Combustibles ............................. 4
Minimum Duct Sizing For Proper Airflow ....................... 6
External Static Pressure Range .............................. 7
Cabinet and Duct Dimensions ............................... 7
Recommended Filter Sizes ................................ 10
High Altitude Conversion .................................. 13
Ratings & Physical ! Electrical Data - Upflow Models ............ 14
Roof Pitch .............................................. 17
Horizontal Sidewall Venting Clearances ...................... 18
OF TABLES
Estimated Free Area ...................................... 20
Free Area .............................................. 20
Unconfined Space Minimum Area in Square Inches ............. 20
Field Installed Accessories - Non Electrical .................... 23
Inlet Gas Pressure Range ................................. 25
Nominal Manifold Pressure ................................. 25
Filter Performance - Pressure Drop Inches W.C. and (kPa) ........ 27
Blower Performance - CFM ................................ 28
SECTION h SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious iniurv.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious iniurv.
CAUTION indicates a potentially hazardous situation, which, if not
avoided mav result in minor or moderate iniurv. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
_WARNING
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
CAUTION
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
288130-UIM-A-0407

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coleman UGAA075BUJ and is the answer not in the manual?

Coleman UGAA075BUJ Specifications

General IconGeneral
BrandColeman
ModelUGAA075BUJ
CategoryFurnace
LanguageEnglish

Related product manuals