6.5.1 MU unlocked
The mixing unit was not positioned and fixed in the 12o'clock position.
This condition occurs upon actuation of the EMERGENCY STOP button or upon interruption of the
power supply during the mixing process.
6.5.2 AUTO
With the container clamped or the mixing unit not loaded, the mixing unit can be automatically
positioned and fixed with the help of Button I (Auto)
6.5.3 MANU
With the mixing container unclamped, the mixing unit must be positioned manually.
Upon actuation of Button III (MANU), the door can be opened by pressing the DOOR button.
Remove mixing unit from the mixing space and fix mixing unit manually in 12o'clock position
Quit manual positioning by pressing the E button
Press Button
for positioning
Press Button
for positioning
Press DOOR
for opening Door
MU locked
Close Door