7. Errors and Troubleshooting
The troubleshooting tables in this Chapter will help you to determine whether you can troubleshoot yourself or whether you need to call
customer service.
IMPORTANT
Jot down the serial number of the machine and the error code from the display before you call customer service. The machine's serial
number is on the type plate.
7.1 Possible errors
Fault Description Machine condition Solutions
E010 Door open
Door open
Close door
Door closed
Check the door lock
Check the power cord / plug to the door lock.
E020 EMERGENCY STOP
activated
EMERGENCY STOP button pushed
Release the EMERGENCY STOP
EMERGENCY STOP button not
pushed
Check the switch of the EMERGENCY STOP button
Check the power cord / plug to the EMERGENCY STOP
button.
E050 Defective container
Container is defect
Container is unstable
Check clamping pressure, if necessary adjust
E070 Mixing Unit locked
Latching pin blocked
The latching pin is blocked clean and lubricate,
replace if necessary
Latching pin released Check the lead/connector to the switch of the mixing
unit magnet
The switch of the mixing unit magnet is defective
E080 Mixing Unit unlocked
Latching pin blocked
The mixing unit is not 12 at o'clock position, see
capter 6.5.1
Check the lead/connector to the switch of the latching
pin
The switch of the latching pin is defective
Latching pin released Check the lead/connector to the switch of the mixing
unit magnet
The switch of the mixing unit magnet is defective
E120 Mixing speed too low
The mixing unit rotates
Check the lead/connector to the "position"
proximity switch
The "position" proximity switch is defective
The mixing unit does not rotate
Check frequency converter
Check the door safety switch
Check the main motor
E130 Mixing speed too high
The mixing unit rotates too fast
Decrease the motor speed
E150 Error clamp motor
The mixing container is not
clamped
Check the clamp motor
Check the lines to the clamp motor
Check the control

Related product manuals