Selecting Sources and Sensors. In the Layer Properties List, click on either Source
or Sensor to open the Source/Sensor conguration window.
23
Chapter 3 Program Control
Select a material. Scroll down and click on the Material row to open the Materials List.
Select the applicable material and double-click a material or click OK. The correct
density and Z-Factor is automatically set.
Click the image to congure which sensors and sources will be used during
deposition. Select one of four congurations:
Source 1 è Sensor 1
Source 2 è Sensor 1
Source 1 è Sensor 2
Source 2 è Sensor 2
If the material being applied in your process is unlisted, select Custom and click OK. You
can then manually enter your custom Density and Z-Factor settings in the Layer Properties
List. Note also that whenever you manually change Density and Z-Factor settings to an
unlisted material, the software will automatically classify the material as “Custom”.
Source and sensor selector.
Materials list.