6 S.P.E.C. 3
®
LED Curing LIght
EN
III. Parts and Descriptions
As you remove each item from the box, ensure all box contents
are in good condition. If items are missing or damaged, contact
your supplier for immediate assistance.
1. HANDPIECE
The handpiece is equipped with high-power
LEDs and its control panel is located on the
front part.
2. LIGHT GUIDE
(8MM TURBO)
The output of the Curing Light LED is emitted
from the end of this piece (autoclavable).
3. LIGHT SHIELD
This shield protects the eyes from the light
emimited from the light guide during use.
4. CHARGER BASE
(6V DC, 2.5A)
The charger base is for the cordless curing
light only. Always place the handpiece on the
charger base when not in use.
5. POWER ADAPTER
Please use the original power adapter at all
times.
6. AC POWER CORD
Please use original AC power cord (at all
times).
7. OWNER’S GUIDE
S.P.E.C. 3
®
LED Curing Light Owner’s Guide.
8. BARRIER SLEEVES
Use for infection control.
9. COMPOSITE CURING
TEST BLOCK
Test curing times and depth of cure.
2.5. Safety Notes
1. Before use, check if the device is working properly and has
no visible damage.
2. The ber-optic light guide is provided in a non-sterile
condition and must be sterilized prior to patient contact.
3. In case of device malfunction, discontinue use and
refer to the ‘Trouble shooting’ section in this Owner’s
Guide. If the problem persists, contact our service center
immediately.
4. Do not attempt to repair, disassemble or remodel
this product without the manufacturer’s permission
(Coltène
®
). Otherwise, product warranty will be voided.
5. The handpiece is not autoclavable. Do not sterilize the
handpiece by immersion or heat sterilization such as dry
heat, steam under pressure, or unsaturated chemical
vapor (ber-optic light guide and light shield can be
autoclaved).
6. Using barrier sleeves will reduce the light output by
5-10%. Due to the high output power of the S.P.E.C.
3
®
LED Curing Light, curing has been shown to be
substantially equivalent.
2.6 Environment Protection
This appliance is labeled in accordance with European directive
2002/96/EC concerning used electrical and electronic appliances
(waste electrical and electronic equipment–WEEE). This guide-
line determines the framework for the return and recycling of
used appliances as applicable throughout the EU. The symbol on
the product, or on the documents accompanying the product,
indicates that this appliance may not be treated as household
waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment.
1
4
5
6
8
9
Owner’s Guide
7
10
11
12
2
3

Table of Contents