DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-2
Extension Classes of service - all calls allowed
Account Code Access Code - 79
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are interactive LCD button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
! * and then enter the DB Admin password
########.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Input 05-02.
Press [save
savesave
save].
Press [show
showshow
show]. The Account Code database item “LENGTH” displays.
Press [chg
chgchg
chg] (change) until the appropriate account code length displays.
Enter the new length and then press [save
savesave
save].
Press [next
nextnext
next]. The account code database item “PASSWORD” displays.
Press [show
showshow
show]. The ID Number of the account code to be changed is required.
Enter the account code number 001-600 to change/display.
Press [show
showshow
show]. The existing programming displays. (“NULL” = empty.)
Press [chg
chgchg
chg].
Enter the account code using the digits 0-9 on the dial pad. When the correct number of digits are entered
(according to the designated length), press “save.” This database item is then updated.
Press [next
nextnext
next]. The Class of Service for this account code displays.
Press [chg
chgchg
chg] until the appropriate Class displays for this account code password.
Press [next
nextnext
next]. The item “DISABLED” displays. This setting is used temporarily disable the use of a particular
Account Code without removing its programming. “DISABLED” means that this account code is active.
Press [
chg
chgchg
chg] to select “Y” orN” to disable this account code password.
Press [next
nextnext
next] to continue programming other account codes. Or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«. The program title page displays.
Press any key at the program title page to enter the Main Menu.
Select PC-DBA from the Main Menu. The PC-DBA menu is then shown.
Select Programming from the PC-DBA menu.
Use
¢£¤¥ to highlight “RESTRICTION” and then press «.
Use
¢£¤¥ to highlight “Account Code Table” and then press «. The cursor is now positioned on
the database item - account code “LENGTH.”
Press « to change this item. Or move the cursor to another item. Note: Changing the account code length
will delete all previously programmed account codes!
Move the cursor as required to the database item to be changed.