COMEM manuale uso RIS 2010 7:COMEM Uso RIS 6-12-2010 9:48 Pagina 10
TOOLS PRECISION
THERMOSTATS
OVERPRESSURE SWITCHES
THERMOMETERS
±3% accuracy tolerance of end scale
±10% accuracy tolerance of end scale
±3% accuracy tolerance of end scale
9
WIRING DIAGRAM
(BY EN 50005 STANDARD)
TEMP.
STOP
“T1”
TEMP.
ALARM
“T2”
PRESSURE
OIL
LEVEL
VOLTAGE
MAKING CAPACITY
BREAKING CAPACITY
Contacts interruption power
OIL LEVEL/GAS BLEED
24V d.c. to 220 V d.c.
2A
100 mA
L/R < 40 ms
Contacts interruption power
PRESSURE SWITCH
230V a.c.
2A
2A
cos φ > 0,5
Contacts interruption power
THERMOSTAT
DEGREE OF PROTECTION (CEI-EN 60529)
DEGREE OF SHOCK TIGHTNESS (EN50102)
SALT-FOGTIGHT
UV-RAY RESISTANCE (UNI-ISO 4892 / UNI-ISO 4582)
TEMPERATURE RESISTANCE
CABLE CONNECTION
CABLE BOX (EN 50005 / EN 60947-7-1 / IEC 947-7-1)
WIRE SECTION TO BE USED ON CLAMP BOX
MAX. RATED PRESSURE
ELECTRICAL CARACTERISTICS
IP66
IK 07
1000 h
500 h
-40 °C ÷ +120 °C
M25x1,5
ACCORDING TO STANDARD
UNTILL 2,5 mm
2
500 mbar
INSULATED ENCLOSURE
GENERAL FEATURES