INSTRUCTIONS FOR TECHNICAL PERSONNEL
14
5) STEAM EXHAUST (*)
The condensed steam exhaust shall have an appropriate slope toward the
recovery installation or a blow-by pump, in order to guarantee an
autonomous scavenging of the condensed steam.
_______________________
(*) for steam machines only
6) LOADING AND UNLOADING OF THE MACHINE
For the transportation of the machine from the delivery point to the final
installation position, use a fork lift or adequate lifting equipment used by
authorised staff. Lift the machine by its frame, taking care that any
protruding parts are not damaged (discharges, wiring etc.).
7) MACHINE DISMANTLING
At the end of its normal lifetime, the machine has to be taken apart according
to the local regulations in force by separating the components as follows:
metal parts: hood, platforms, frames, filters
electrical parts: motors, remote control switches, microswitches, wiring
plastic parts: racks, connections
rubber parts: tubes, sleeves