42
-
bottlenecks in the intake circuit (inadequate pipe section, dirty lter, very dense liquid being
pumped, etc)
-
the use of very aggressive chemicals
7.2 SPECIAL MAINTENANCE
«
CAUTION
Only Skilled Technicians are authorised to carry out special maintenance.
Dispose of waste oil correctly; do not throw it away in the environment
Follow the instructions in the table below for special maintenance.
WARNING
The data in the table are indications. Maintenance may be required more frequently in cause of
particularly heavy use.
8. DISMANTLING AND DISPOSAL
Only trained personnel are allowed to dismantle the pump in accordance with the current regulations
in the country where it is installed.
9. PROBLEMS, CAUSES AND SOLUTIONS
«
CAUTION
Before undertaking any action, follow the instructions in the
“SWITCHING OFF”
section.
“SWITCHING OFF” section. “SWITCHING OFF”
If it is not possible to restore correct operation of the pump using the information in the table
below, contact a
Skilled Technician.
INTERV
AL FOR MAINTENANCE
INTERVAL FOR MAINTENANCEINTERV
ACTION
Every 300 hours
At the end of every season
or once a year
Check the intake and delivery valves (1)
Check diaphragms and r
eplace if necessary (2)
Replace the oil (3)
Check the pump scr
ews ar
e tight (4)
1)
check mor
e fr
equently if liquids ar
e used with suspended abrasive particles.
2)
we r
ecommend r
eplacing diaphragms r
egar
dless of their condition if particularly aggr
essive
essive
chemicals ar
e used.
3)
Oil must be changed when diaphragms ar
e r
eplaced; first oil change must take place
after 300 hours
4)
check mor
e fr
equently if the pump operates in conditions of heavy vibration.
PROBLEM
CAUSE
SOLUTION
The pump does not prime
The pump does not r
each
maximum pr
essur
e.
Irr
egular pr
essur
e
and water flow (pulsating)
Excessive vibration in delivery cir
cuit
Excessive noise associated
with dr
op in the oil level
Excessive consumption of oil
and/or oil is whitish colour
(pr
esence of water in oil)
W
ater intake
Adjustment valve positioned
under pr
essur
e
Speed of pump r
otation is inadequate
Unsuitable application
(for example: wor
n nozzle or too lar
ge nozzle)
W
ater intake
Pr
essur
e accumulator not corr
ectly inflated
Bottlenecks in intake cir
cuit
Ruptur
e of one or mor
e diaphragms
Check the intake cir
cuit is intact
Set pr
essur
e to zer
o
and put pump in bypass
Restor
e corr
ect r
otation speed
Replace application
Check the intake cir
cuit is intact
Restor
e corr
ect inflation
Check intake cir
cuit
Refer to instructions in section 7.1.1.