Only model DSG-CAR 3 EXVF
(FOAM):
To select the suction power (from level 1 to
level 4), press the remote suction button L1
on the handgrip at short intervals; the se-
lected suction power level LED indicator will
light up. It is possible to change the power
level both when the suction is on and o. To
switch the vacuum on and o, hold down
the remote suction button L1 for about two
seconds.
When work is nished, release the steam le-
ver L3 a few moments prior to switching o
the suction motor L1. This will allow the suc-
tion ducts to recover the humidity.
FOAM CLEANING
Only model DSG-CAR 3 EXVF:
Connect the device to a minimum 5 bar
air compressor (not supplied).
Using specic detergents is indispensa-
ble for foam production.
Insert antifoam additive in the tank, 50 cc.
Insert the compressed air tting hose in V1
(hose not supplied).
Adjust the air pressure from 2 to 5 bar with
knob V3.
Fit the most suitable accessory in the handle
of the exible hose L.
Connect the device to a suitable electrical
outlet.
Start by pressing main switch B.
Selection switch P1 to the air position
AIR (II)
Selection switch P to position
(I) detergent.
For foam outow, press lever L3
Distribute the foam.
Leave the detergent on for 1 minute.
Vacuum by pressing button L1
To select the suction power (from level 1 to
level 4), press the remote suction button L1
on the handgrip at short intervals; the se-
lected suction power level LED indicator will
light up. It is possible to change the power
level both when the suction is on and o. To
switch the vacuum on and o, hold down the
remote suction button L1 for about two sec-
onds.
RINSING WITH AIR AND WATER
Only model
DSG-CAR 3 EXVF:
Connect the device to a minimum 5 bar
air compressor (not supplied).
Insert the compressed air tting hose in
V1 (
hose
not supplied)
Adjust the air pressure to the maximum with knob
V3
.
Fit the most suitable accessory in the handle
of the exible hose L.
Connect the device to a suitable electrical
outlet.
Start by pressing main switch B.
Selection
switch
P1
to the position
AIR
(II)
Selection
switch
P
to the position
H2O (II)
water
For air and water outow, press lever
L3
Vacuum by pressing button
L1
.
To select the suction power (from level 1 to
level 4), press the remote suction button L1
on the handgrip at short intervals; the se-
lected suction power level LED indicator will
light up.
TOPPING UP THE BOILER WATER TANK WITH WA-
TER
The boiler water tank L supplies the boiler
through an electronic level control; since this
is an external tank, it can be topped up any
time.
When water runs out in the boiler water
tank:
1. the appliance beeps intermittently
2. the no-water level pilot light C ashes
3. the steam stops coming out
To top up, proceed as follows:
• Switch o the boiler switch E