INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS
INSTALLATIONPOWER UPSETUPUSAGE GUIDEADVANCED MENUS
14
23
th e r M o s t a t se t -u P
ad v a n c e d In s t a l l e r co n f I g u r a t I o n Me n u
1
2
Select Continuous FAN speed. Default fan
speed is Medium. The fan speed can be set
to High, Medium or Low. In High, the fan
will run at 70% of the highest fan speed. In
Medium, the fan speed will be 50% of the
highest fan speed. In Low, the fan speed
will be approximately 30% of the highest
fan speed.
Select program days per week. Scrolling
message will show PROGRAM TYPE.
Default is 7 Days to indicate 7 program
days a week. It can be changed to 0 Days
to indicate no programs will be run. When
set for 7 Days, the thermostat will follow
the factory program or the program that
you entered.
Select Energy Management Recovery.
Scrolling Message will show ENERGY
MANAGEMENT RECOVERY”. (Will not
appear if Program days per week is set to
0 Days.) When selected On, the thermostat
will begin heating or cooling early to
have the building temperature reach the
program set-point at the program period
start time.
Example: The heating program is 65°F at
night and 70°F at 7 AM for the Morning
period. The building temperature is 65°F, a
dierence of 5°F. Allowing 5 minutes per °F
rise, the thermostat will begin the system at
6:35 AM to reach 70°F at 7 AM.
1
2
1
2
eQ u i P m e n t uS e r me n u S
Each Equipment User Menu has sub-menus to divide the information into categories.
Each piece of equipment has a dierent set of sub-menus, with dierent parameters
depending on the equipment. The sub-menus are showing the similar information for
each piece of equipment. The sub-menus and information they provide are:
Conguration: This sub-menu item provides access to information regarding the
conguration of the particular piece of equipment. An example of conguration data
is the number of cooling stages for an AC condensing unit.
Diagnostics: This sub-menu item provides access to the fault history for the particular
piece of equipment. It also provides a means to clear the fault history.
Identication: This sub-menu item provides access to the model number and serial
number (optional) for the particular piece of equipment.
Sensors: This sub-menu item provides access to available sensor data for the
particular piece of equipment. In some instances, it may also provide a means to
enable or disable a particular sensor. This sub-menu may not be available for all
equipment.
Set-up: This sub-menu item provides access to modiable operational parameters
for the particular piece of equipment.
Status: This sub-menu item provides access to the current status of a particular piece
of equipment.
The following sections provide detailed listings of the available sub-menus for the various
types of equipment that may be used with this digitally communicating thermostat. The
sub-menu listing is further broken down into the various sub-menu items.